Abstract:

For today it is possible to allocate two basic strategies of images primary analysis during virtual colonoscopy (VC): it means interpretation on the basis of 2D and 3D reconstruction data

Purpose. Was to compare 2D and 3D analysis programs during VC: they were compared on interpretation time,on sensitivity of polyp's detection

Materials and methods. The research consisted of 80 patients. All detected new growth during VC were put into protocols of interpretation, with instructions of quantity, form and size

All the patients were underwent VC, including biopsy and further histological research Also, time spent for analysis of each research was fixed

Conclusions. Sensitivity of 3D virtual dissection during primary imaging analysis in almost the same in comparison with 2D, but interpretation time is higher in 2D.  

 

References 

1.    Barish   M.A.,   Soto  J.A.,   Ferrucci  J.T. Consensus on current clinical practice of virtual colonoscopy. Am. J. Roentgenol. 2005; 184: 786-792.

2.    Pickhardt PJ. et al. Computed tomographic virtual colonoscopy to screen for colorectal neoplasia in asymptomatic adults. N. Engl. J. Med. 2003; 349: 2191- 2200.

3.    Taylor S.A. et al. Polyp detection with CT colonography. Primary 3D endoluminal analysis versus primary 2D transverse analysis with computer-assisted reader software. Radiology.2006; 239: 759-767.

4.    Yasumoto T. et al. Assessment of two 3D MDCT colonography protocols for observation of colorectal polyps. Am. J. Roentgenol. 2006; 186: 85- 89.

5.    Sorstedt E. et al. Computed tomographic colonography. Сomparison of two workstations. Acta. Radiol. 2005; 46: 671-678.

6.    Macari M. et al. Comparison of time-efficien CT colonography with two- and three-dimensional colonic evaluation for detecting colorectal polyps. Am. J.Roentgenol. 2000; 174: 1543-1549.

7.    Hoppe H. et al. Virtual colon dissection with CT colonography compared with axial interpretation and conventional colonoscopy. Preliminary results. Am. J. Roentgenol. 2004;182: 1151-1158.

8.    Paik D.S. et al. Visualization modes for CT colonography using cylindrical and planar map projections. J.Comput. Assist. Tomogr. 2000; 24: 79-188.

9.    Rottgen R. et al. Colon dissection. А new three-dimensional reconstruction tool for computed tomography colonography. Acta. Radiol. 2005; 46: 222-226.

10.  Dekel D., Durgan J., Fleiter T. Virtual endo-scopy (patent pending). Publication no 2006/000925. Geneva, Switzerland: World Intellectual Property Organization. 2006.

11.  Хомутова Е.Ю. и др. Устройство для раздувания толстой кишки. Патент на полезную модель № 71072 от 14.05.2007 г. 2008.

12.  Juchems M.S. et al. CT colonography. Сomparison of a colon dissection display versus 3D endoluminal view for the detection of polyps. Eur. Radiol. 2006; 16: 68-72.

13.  Pickhardt P.J. et al. Flat colorectal lesions in asymptomatic adults. lmplications for screening with CT virtual colonoscopy. Am. J. Roentgenol. 2004; 183: 1343-1347.

 

ANGIOLOGIA.ru (АНГИОЛОГИЯ.ру) - портал о диагностике и лечении заболеваний сосудистой системы