Aim: was to evaluate the safety and efficacy of coronary stents «MedEng» and to compare them with results of the use of other coronary stents.

Materials and methods: the study included 147 patients with coronary artery disease, which in the period from January to March 2014 underwent coronary stenting. Stents «MedEng» were implanted in 61 patients (group 1). The second group (control) consisted of 86 patients who underwent implantation of stents «Driver». Average follow-up was 6,2±0,5 months. Endpoints were: the return or retention of not less than 2 angina functional class (on CCS); death by cardiac causes, myocardial infarction (MI), repeated intervention on the target vessel, restenosis> 50%, confirmed by angiography and/or the data of optical coherence tomography (OCT)

Results: success rate of stenting was 100%. Death and MI during follow-up were not observed. Restenosis was observed in 9(14,7%) patients in group «MedEng» and in 13 (15,1%) patients from «Driver» group (p = 0,9). The average degree of coronary restenosis was 76,1±8,4% and 76,2±6,4% in the first and second groups, respectively (p=0.9). According to results of logistic regression, stents «MedEng» was not a predictor of restenosis (OR=1,998; 95% CI (0,158-312,551); p = 0,314).

Conclusions: the use of stents «MedEng» is safe and effective in myocardial revascularization. Results of implantation of stents «MedEng» do not different from results of the use of stents «Driver».  

 

References 

1.    Hoffmann R., Mintz G. Coronary in-stent restenosis - predictors, treatment and prevention. European Heart Journal 2000; 21: 1739-1749.

2.    Ben-Dor I., Waksman R., Pichard A.et al. The Current Role of Bare-Metal Stents. Cardiac interv. 2011; 1: 57-62.

3.    Kastrati A., Sch^mig A., Elezi S., Dirschinger J et al. Prognostic Value of the Modified American College of Cardiology/American Heart Association Stenosis Morphology Classification for Long-Term Angiographic and Clinical Outcome After Coronary Stent Placement. Circulation. 1999; 100: 1285-1290.

4.    Lagerqvist B., James S., Stenestrand U., Lindbck J., Nilsson T., Wallentin L. Long-term outcomes with drug-eluting stents versus bare-metal stents in Sweden. N. Engl. J. Med. 2007; 356: 1009-1019

5.    Sketch M., Ball M., Rutherford B., Popma J.J., Russell C., Kereiakes D.J. Driver Investigators. Evaluation of the Medtronic (Driver) cobalt-chromium alloy coronary stent system. Am. J. Cardiol. 2005;95:8-12.

6.    Farb A., et al., Pathology of acute and chronic coronary stenting in humans. Circulation. 1999; 99(1): p. 44-52.

7.    Sarno G., et al. Lower risk of stent thrombosis and restenosis with unrestricted use of newgeneration drug-eluting stents: a report from the nation wide Swedish Coronary Angiography and Angioplasty Registry (SCAAR). Eur. Heart J. 2012; 33(5): p. 606-13.

8.    Camenzind E., Steg P., Wijns W. Stent thrombosis late after implantation of First-generation drug-eluting stents: a cause for concern. Circulation. 2007; 115: 1440-155.

9.    Lagerqvist B., James S., Stenestrand U., Lindbck J., Nilsson T., Wallentin L. Long-term outcomes with drug-eluting stents versus bare-metal stents in Sweden. N.Engl. J. Med. 2007; 356: 1009-1019.

10.  Bavry A., Kumbhani D., Helton T., et al. Late thrombosis of drug-eluting stents: a metaanalysis of randomized clinical trials. Am. J. Med. 2006;119:1056-1061.

11.  Morice M., Urban P., Greene S., Schuler G., Chevalier B. Why are we still using Coronary Bare-Metal Stents? JACC. 2013;61;1122-3.

12.  Steinberg D., Mishra S., Javaid A., et al. Comparison of effectiveness of bare metal stents versus drug-eluting stents in large (>3.5 mm) coronary arteries. Am. J. Cardiol. 2007;99:599-602.

13.  Kim T., Nam C., Hur S., et al. Two-year clinical outcomes after large coronary stent (4.0 mm) placement: comparison of bare-metal stent versus drug-eluting stent. Clin. Cardiol. 2010;33:620-625.

14.  Bocksch W., Pomar F., Dziarmaga M., Tresukosol D et al. Clinical safety and efficacy of a novel thin-strut cobalt-chromium coronary stent system: results of the real world Coroflex Blue Registry. Catheter Cardiovasc. Interv. 2010 Jan 1;75(1):78-85.

15.  Cassese S., Byrne R., Tada T. et al. Incidence and predictors of restenosis after coronary stenting in 10 004 patients with surveillance angiography. Heart.2014 Jan;100(2):153-9.

16.  Serruys P., Morice M., Kappetein A., et al. SYNTAX Investigators. Percutaneous coronary intervention versus coronary-artery bypass grafting for severe coronary artery disease. N. Engl. J. Med. 2009;360:961-972.

 

ANGIOLOGIA.ru (АНГИОЛОГИЯ.ру) - портал о диагностике и лечении заболеваний сосудистой системы