Website is intended for physicians
Search:

 

 Abstract:

Aim: was to compare endothelialization of stents with permanent and biodegradable coatings at an early stage with help of optical coherence tomography (OCT).

Materials and methods: this study is a prospective, randomized trial that includes a comparative analysis of OCT data in patients after implantation of coronary stents with biodegradable (study group) and permanent coatings (control group). 98 patients were randomized 1:1 into 2 groups. After 3 months, 10 patients from each group - were randomized to conduct OCT.

Results: we analyzed OCT data of 10 studies in the biodegradable group (1,776 struts and 247 sections) and 10 studies in the permanent coating group (1562 struts and 226 sections). There were no differences in proportion of uncovered (8,9% vs. 8,5%, p=0,49) and non-exposed struts (1,6% vs. 1,3%, p=0,2). Thus, 98,4% of struts in study group and 98.7% in control group were endothelialized.

Conclusions: according to OCT data, similar results were obtained in both groups. After 3 months of observation in two groups, the overwhelming number of struts were endothelialized. At the early stage of observation, none of groups, achievement of endpoints was detected. 

 

References

1.     Mauri L., Kereiakes D., Yeh R. et al. Twelve or 30 Months of Dual Antiplatelet Therapy after Drug-Eluting Stents. N Engl J Med. 2014; 371:2155-2166.

2.     Authors/Task Force members , Windecker S., Kolh P., et al. ESC/EACTS Guidelines on myocardial revascularization: The Task Force on Myocardial Revascularization of the European Society of Cardiology (ESC) and the European Association for Cardio-Thoracic Surgery (EACTS) Developed with the special contribution of the European Association of Percutaneous Cardiovascular Interventions (EAPCI). Eur Heart J. 2014;35:2541-619.

3.     Kim S., Kim J.S., Shin D.H., et al. Comparison of early strut coverage between zotarolimus- and everolimus-eluting stents using optical coherence tomography. Am J Cardiol. 2013;111:1-5.

4.     Izumi D., Miyahara M., Sakai M., Fukuoka S. OCT- based comparison of early strut coverage between zotarolimus- and everolimus-eluting stents with second stent designs. Eurointervention. 2014;5;20.

5.     Ormiston J., Webster M., Stewart J. et al. First-inHuman Evaluation of a Bioabsorbable Polymer-Coated Sirolimus-Eluting Stent. JACC: Cardiovasc int 2013; 6(10): 1026-1034.

6.     Karjalainen P, Varho V., Nammas W. et al. Early Neointimal Coverage and Vasodilator Response Following Biodegradable Polymer Sirolimus-Eluting vs. Durable Polymer Zotarolimus-Eluting Stents in Patients With Acute Coronary Syndrome. Circulation Journal .2015;79(2): 360-367. 

ANGIOLOGIA.ru (АНГИОЛОГИЯ.ру) - портал о диагностике и лечении заболеваний сосудистой системы