Website is intended for physicians
Search:

 

Abstract:

Background and purpose: flow-diverting devices are increasingly used for the treatment of giant and wide neck cerebral aneurysms. The aim of the research was to evaluate the feasibility of computed tomography angiography CTA in the postoperative evaluation of aneurysms treatec with Pipeline Embolization Device (PED).

Materials and methods: fifteen patients with 19 aneurysms treated by total of 17 PED were examined by means of CTA. Postprocessing of CTA acquisitions were done at workstation using maximum intensity projections, multiplanar reformations, curved planar reformations and volume rendering of PED region and other intracranial arteries. The position of PED and dergree of aneurysm occlusion were evalluated.

Results: CTA follow-up of at least 26 months demonstrated complete occlusion of aneurysms treated with the PED in 9 cases (50%). There were 2 cases (11,1%) of proximal stent migration and 2 cases (11,1%) of stent narrowing due to incomlete expansion. Flow reduction was observed in 4 aneurysms (22,2%). CTA was accurate in determining the position of PED and evaluating the patency of aneurysm.

Conclusions: CTA can be used as a reliable tool for postoperative evaluation of aneurysms treated with PED defining the stent position and aneurysmal flow reduction. Postprocessing using curved planar reformations with window width 1000-2500 and level 600-800 is optimal for stent visualization.  

 

References

1.     Suzuki S., Tateshima S., Jahan R., Duckwiler G.R., Murayama Y, Gonzalez N.R., V^uela F. Endovascular treatment of middle cerebral artery aneurysms with detachable coils: angiographic and clinical outcomes in 115 consecutive patients. Neurosurgery. 2009; 64(5): 876-88.

2.     V^uela F., Duckwiler G., Mawad M. Guglielmi detachable coil embolization of acute intracranial aneurysm: perioperative anatomical and clinical outcome in 403 patients. J. Neurosurgery. 2008; 108(4): 832-9.

3.     Kallmes D.F., Ding YH., Dai D., Kadirvel R., Lewis D.A., Cloft H.J. A new endoluminal, flow-disrupting device for treatment of saccular aneurysms. Stroke. 2007; 38(8): 2346-52.

4.     Lylyk P, Miranda C., Ceratto R., et al. Curative endovascular reconstruction of cerebral aneurysms with the Pipeline embolization device: the Buenos Aires experience. Neurosurgery. 2009; 64: 632- 42, discussion 642-43, quiz N636.

5.     Cloft H.J., Joseph G.J., Dion J.E. Risk of cerebral angiography in patients with subarachnoid hemorrhage, cerebral aneurysm, and arteriovenous malformation: a meta-analysis. Stroke. 1999; 30(2): 317-20.12.

6.     Mayberg M.R., Batjer H.H., Dacey R., Diringer M., Haley E.C., Heros R.C., Sternau L.L., Torner J., Adams H.P Feinberg W. et al. Guidelines for the management of aneurysmal subarachnoid hemorrhage. A statement for healthcare professionals from a special writing group of the Stroke Council, American Heart Association. Stroke. 1994; 25(11): 2315-28.

7.     Min J.K., Swaminathan R.V., Vass M., Gallagher S., Weinsaft J.W. High-definition multidetector computed tomography for evaluation of coronary artery stents: comparison to standard-definition 64-detector row computed tomography. Cardiovasc. Comput. Tomogr. 2009; 3(4): 246-51.

8.     Sun Z., Davidson R., Lin C.H. Multi-detector row CT angiography in the assessment of coronary in-stent restenosis: a systematic review. Eur. J. Radiol. 2009; 69(3): 489-95.

9.     Szikora I., Guterman L.R., Wells K.M., Hopkins L.N. Combined use of stents and coils to treat experimental wide-necked carotid aneurysms: preliminary results. AJNR Am. J. Neuroradiol. 1994; 15(6):1091-102.

10.   Ternovoy S.K., Akchurin R.S., Fedotenkov I.S., Veselova T.N., Nikonova M.E., Shiryaev A.A. Neinvazivnaya shuntografiya metodom mul’tispiral’noy komp’yuternoy tomografii. REJR. 2011; 1(1): 26-32 [In Russ].

11.   Lieber B.B., Stancampiano A.P, Wakhloo A.K. Alteration of hemodynamics in aneurysm models by stenting: influence of stent porosity. Ann. Biomed. Eng. 1997; 25(3): 460-9.

12.   Szikora I., Berentei Z., Kulcsar Z., et al. Treatment of intracranial aneurysms by functional reconstruction of the parent artery: the Budapest experience with the Pipeline embolization device. AJNR Am. J. Neuroradiol. 2010; 31:1139-47.

13.   McAuliffe W., Wycoco V., Rice H., Phatouros C., Singh T.J., Wenderoth J. Immediate and midterm results following treatment of unruptured intracranial aneurysms with the pipeline embolization device. AJNR Am. J. Neuroradiol. 2012; 33(1):164-70.

14.   Saatci I., Yavuz K., Ozer C., Geyik S., Cekirge H.S. Treatment of intracranial aneurysms using the pipeline flow-diverter embolization device: a single-center experience with long-term follow-up results. AJNR Am. J. Neuroradiol. 2012; 33(8):1436-46.

15.   Deutschmann H.A., Wehrschuetz M., Augustin M., Niederkorn K., Klein G.E. Long-term follow-up after treatment of intracranial aneurysms with the Pipeline embolization device: results from a single center. AJNR Am. J. Neuroradiol. 2012; 33(3): 481-6. 

ANGIOLOGIA.ru (АНГИОЛОГИЯ.ру) - портал о диагностике и лечении заболеваний сосудистой системы