Website is intended for physicians
Search:
Всего найдено: 4

Abstract:

Introduction: one of directions in development of intravascular diagnostic methods is creation of stations or development of methods that allow combining or uniting possibilities of different modalities. This approach makes it possible to overcome limitations inherent in each method of invasive vascular diagnostics, including angiography. This work is devoted to the analysis of possibilities and first results of using the SyncVision station (Philips Volcano), which allows, in various combinations, to carry out joint registration of angiography data, intravascular ultrasound (IVUS) and instantaneous blood flow reserve (iFR) in various combinations - a non-hyperemic version of fractional flow reserve study.

Aim: was to describe possibilities provided by the use of joint recording of data from angiography, IVUS and real-time instantaneous blood flow reserve, the technique for performing these procedures, as well as to analyze the application of these methods in a department with a large volume of intravascular studies.

Material and methods: the first experience in Russian Federation of the clinical use of the SyncVision station, which is an addition to the s5i intravascular ultrasound system (Philips Volcano), is presented. The station allows you to implement five options that expand the operator's ability to analyze study data and develop a treatment strategy directly at the operating table: co-registration of angiography and intravascular ultrasound (IVUS) data; co-registration of angiography data and instantaneous flow reserve (iFR); triple co-registration - angiography, IVUS and iFR; modification of the program for the quantitative calculation of coronary artery stenosis (QCA); real-time image enhancement software for interventional devices.

Results: studies using co-registration with angiography accounted for 21% of all IVUS procedures and 62,4% of iFR procedures. In 67,3% of all studies with angio-IVUS co-registration, the indication for this diagnostic variant was an extended lesion of artery, which required clarification of length of stenotic area, localization of reference segments, and diameter of artery at different levels. In 30 of these patients, triple co-registration was performed. To clarify the hemodynamic significance of lesion with an angiographically indeterminate or borderline picture, co-registration was performed in 13,2% of all cases, to study a bifurcation lesion with a significant difference in the reference segments and angiographically difficult to determine the entry of lateral branch - in 7,3%.

Based on results of triple co-registration, the decision to perform surgical treatment was made in 30 out of 42 patients (71,4%).

Conclusion: joint registration of IVUS data, coronary angiography, and instantaneous flow reserve (iFR) in real time, forms a new diagnostic modality that significantly expands possibilities of intraoperative examination and affects the planning or analysis of intervention results.

 

Abstract:

Introduction: the importance of intravascular diagnostic methods and the frequency of their use in clinical practice is steadily increasing. However, in the Russian Federation, studies on the analysis of possibilities of intravascular imaging or physiology are sporadic, and statistical data are presented only in very generalized form. This makes it relevant to create a specialized register dedicated to these diagnostic methods.

Aim: was to present the structure, tasks and possibilities of the Russian registry for the use of intravascular imaging and physiology based on results of the first year of its operation.

Material and methods: In total, in 2021, forms were filled out for 2632 studies in 1356 patients.

Studies included all types of intravascular imaging and physiology - intravascular ultrasound, optical coherence tomography, measurement of fractional flow reserve and non-hyperemic indices.

The registry's web-based data platform includes 14 sections and 184 parameters to describe all possible scenarios for applying these methodologies. Data entry is possible both from a stationary computer and from mobile devices, and takes no more than one minute per study. Received material is converted into Excel format for further statistical processing.

Results: 13 departments participated in the register, while the share of the eight most active ones accounted for 97,5% of all entered forms. On average, 1.9 studies per patient were performed, with fluctuations between clinics from 1,6 to 2,9. Studies of the fractional flow reserve accounted for 40% of total data array, intravascular ultrasound - 37%, optical coherence tomography - 23%. Of all studies, 80% were performed on coronary arteries for chronic coronary artery disease, 18% - for acute coronary syndrome, 2% were studies for non-coronary pathology. In 41% of cases, studies were performed at the diagnostic stage, without subsequent surgery. In 89,6% of cases, this was due to the detection of hemodynamically insignificant lesions, mainly by means of physiological assessment. In 72% of cases, the use of intravascular imaging or physiology methods directly influenced the tactics or treatment strategy - from deciding whether to perform surgery or not to choose the optimal size of instruments or additional manipulations to optimize the outcome of the intervention. In the clinics participating in the register, the equipment of all major manufacturers represented on the Russian market was used.

Conclusions: the design of the online registry database is convenient for data entry. Participation in the registry of most departments that actively and systematically use methods of intravascular imaging and physiology ensured the representativeness of obtained data for analysis in interests of both practical medicine and industry, as well as for scientific research in the field of intravascular imaging and physiology. The register has great potential for both quantitative and qualitative improvement.

 

Abstract:

Aim: was to analyze long-term resuts of true lumen reconstruction in complicated aortic dissections type В with help of balloon-expandable stents under intravascular ultrasonic (IVUS) guidance as a preoperative evaluation of anatomy and morphology of lesion.

Materials and methods: 47 patients witn type В aortiс dissections underwent endovascular treatment in our departmert n 20 cases - IVUS was used for irtraoperative anatomy and morphology verification. Complications developed n 16 patients, and true lumen was reconstructed by stent-graft implantation (to cover proximal fenestration) followed by balloon-expandable stents implantation at the level of visceral arteries under IVUS control at every stage. 87,5% of patents were man, mean ago 51 8—16,2 years.

Results: Technical success was 100% True lumen total reconstruction was reached in every case under precise IVUS control. Visceral arteries malperfusion was not observed at hospital period or follow-up. З0-day mortality rate was 6,25% (1 case due to aortic rupture in uncovered part of aorta - 7 days after procedure). All 15 discharged patients survived for 1st year. Mean follow-up period is 3,3±1,6 years. One patient died due to aortobronchial fistula, 1 due to repeated stroke and 1 due to cancer. At CT-scan 2 years after implantation (10 cases) fractures of balloon-expandable stents were observed, without аnу influence on intraluminal size or stenotic lesion. True lumen size stayed stable for 1 year.

Conclusion: true lumen reconstruction under IVUS control seems to be feasible and effective in complicated Type B dissections, even with the use of balloon-expandable stents. The usage of additional intraoperative visualization - intraaortic IVUS is the key point in the development of advanced endovascular methods.

 

References

1.      Erbel R., Aboyans V., Boileau C., et al. Task Force for the Diagnosis and Treatment of Aortic Diseases of the European Society of Cardiology (ESC). 2014 ESC guidelines on the diagnosis and treatment of aortic diseases: document covering acute and chronic aortic diseases of the thoracic and abdominal aorta of the adult. Eur Heart J. 2014;35:2873-926.

2.      Fattori R., Cao P., De Rango P, et al. Interdisciplinary expert consensus document on management of type B aortic dissection. J Am Coll Cardiol. 2013; 61: 1661-78.

3.      Eggebrecht H., Nienaber C.A., Neuhauser M., et al. Endovascular stent graft placement in aortic dissection: a metaanalysis. Eur Heart J. 2006; 27: 489e98.

4.      Mossop P.J., McLachlan C.S., Amukotuwa S.A., Nixon I.K. Staged endovascular treatment for complicated type B aortic dissection. Nat Clin Pract Cardiovasc Med. 2005;2:316-21.

5.      Canaud L., Faure E.M., Ozdemir B.A., Alric P., Thompson M. (2014) Systematic review of outcomes of combined proximal stent-grafting with distal bare stenting for management of aortic dissection. Ann Cardiothorac Surg. 3: 223-233.

6.      Nienaber C.A., von Kodolitsch Y, Nicolas V., et al. The diagnosis of thoracic aortic dissection by noninvasive imaging procedures. N Engl J Med. 1993; 328: 1-9.

7.      Evangelista A., Flachskampf F.A., Erbel R., et al. Echocardiography in aortic diseases: EAE recommendations for clinical practice. Eur J Echocardiogr. 2010; 11: 645-658.

8.      Fattori R., Caldarera I., Rapezzi C., et al. Primary endoleakage in endovascular treatment of the thoracic aorta: importance of intraoperative transesophageal echocardiography. J Thorac Cardiovasc Surg. 2000; 120: 490-5.

9.      Rocchi G., Lofiego C., Bigini E., et al. Transesophageal echocardiography-guided algorithm for stent-graft implantation in aortic dissection. J Vasc Surg. 2004; 40: 880-5.

10.    Morton J.B., Sanders P., Sparks P.B., et al. Usefulness of phased-array intracardiac echocardiography for the assessment of left atrial mechanical “stunning” in atrial flutter and comparison with multiplane transesophageal echocardiography. Am J Cardiol. 2002; 90: 741-6.

11.    Marrouche N.F., Martin D.O., Wazni O., et al. Phased-array intracardiac echocardiography monitoring during pulmonary vein isolation in patients with atrial fibrillation: impact on outcome and complications. Circ 2003; 107: 2710-6.

12.    Caldararu C., Balanescu S. Modern Use of Echocardiography in Transcatheter Aortic Valve Replacement: an Up-Date. M&dica. 2016; 11(4): 299-307.

13.    Jongbloed MR.M., Schalij M.J., Zeppenfeld K., et al.Clinical applications of intracardiac echocardiography in interventional procedures. Heart. 2005; 91(7): 981-990. doi:10.1136/hrt.2004.050443.

14.    Kang S.J., Ahn J.M., Kim W.J., et al. Intravascular ultrasound assessment of drug-eluting stent coverage of the coronary ostium and effect on outcomes. Am J Cardiol. 2013; 111: 1401-7.

15.    Hitchner E., Zayed M.A., Lee G., et al. Intravascular ultrasound as a clinical adjunct for carotid plaque characterization. J Vasc Surg 2014; 59: 774-80.

16.    Diethrich E.B., Irshad K., Reid D.B. Virtual histology and color intravascular ultrasound in peripheral interventions. Semin Vasc Surg. 2006; 19: 155-62.

17.    Song T.K., Donayre C.E., Kopchok G.E., White R.A. Intravascular ultrasound use in the treatment of thoracoabdominal dissections, aneurysms, and transections. Semin Vasc Surg. 2006; 19: 145 9.

18.    Pearce B.J., Jordan W.D. Jr. Using IVUS during EVAR and TEVAR: Improving patient outcomes. Semin Vasc Surg. 2009; 22: 172 80.

19.    Lee J.T., White R.A. Basics of intravascular ultrasound: An essential tool for the endovascular surgeon. Semin Vasc Surg. 2004; 17: 110 8.

20.    Gol'dina I.M., Trofimova E.Yu., Kokov L.S., Parxomenko M.V., Chernaya N.R., Sokolov V.V., Redkoborody'j A.V., Rubczov N.V. Possibilities of intravascular ultrasound examination using a phased array catheter sensor in the diagnosis and treatment of aortic dissection. Ultrazvukovaya i funktsiomalnaya diagnostika. 2016; 1: 78-89 [In Russ].

21.    Martin Z.L., Mastracci T.M. The evaluation of aortic dissections with intravascular ultrasonography. Vascular Disease Management. 2011; 03(31). Available at: http://www.vasculardiseasemanagement.com/content/ev aluation-aortic-dissections-intravascular-ultrasonography/ (accessed 10 march 2018).

22.    Eggebrecht H., Nienaber C.A., Neuhauser M., et al. Endovascular stent graft placement in aortic dissection: a metaanalysis. Eur Heart J. 2006; 27: 489e98.

23.    Mossop P.J., McLachlan C.S., Amukotuwa S.A., Nixon I.K. Staged endovascular treatment for complicated type B aortic dissection. Nat Clin Pract Cardiovasc Med. 2005; 2: 316e22.

24.    Nienaber C.A., Kische S., Zeller T., et al. Provisional extension to induce complete attachment after stent graft placement in type B aortic dissection: the PETTICOAT concept. J Endovasc Ther. 2006; 13: 738e46.

25.    Lombardi J.V., Cambria R.P, Nienaber C.A., et al. Prospective multicenter clinical trial (STABLE) on the endovascular treatment of complicated type B aortic dissection using a composite device design. J Vasc Surg. 2012; 55: 629e40.

26.    Hoshina K., Kato M., Miyahara T., et al. Retrospective study of intravascular ultrasound use in patients undergoing endovascular aneurysm repair: Its usefulness and a description of the procedure. Eur J Vasc Endovasc Surg. 2010; 40: 559-63.

27.    Guo B-L., Shi Z-Y, Guo D-Q., et al. Effect of Intravascular Ultrasound-assisted Thoracic Endovascular Aortic Repair for «Complicated» Type B Aortic Dissection. Chinese Medical Journal. 2015; 128(17): 2322-2329.

 

Abstract:

The article presents a literature review of the use of optical coherence tomography in interventional cardiology. The method of optical coherence tomography is described in details, as well as its comparison with other methods of intravascular imaging. Direct results of the use of optical coherence tomography in clinical practice in the performance of percutaneous coronary intervention have been analyzed. Article describes possibilities of assessment of long-term results after interventional procedures using optical coherence tomography in patients with coronary heart disease. Article notes possibilities of using optical coherence tomography to assess the effectiveness of treatment of patients with atherosclerotic coronary pathology using biodegradable stents.

 

References:

1.     Hiram G. Bezerra., Marco A. Costa., Guagliuni G. et al. Intracoronary Optical Coherence Tomography: A Comprehencive Review: Clinical and Research Applications. J.Am.Col. Cardiol. Intv. 2009; 42:1035-1046.

2.     Rollings A.M.,Ung-arunyawee R., Chak A., Wong R.C.K., Kobayashi K., SWivak M.V., Izatt J.A. Real time in vivo imaging of human gastrointestinal ultrastructure by use of endoscopic optical coherence tomography with a novel efficient interferometer design. Opr.left. 1999;24(19): 1358-1360.

3.     Adam M., Nguyenet F. T., Daniel L. M. et.al. Optical coherence tomography: a review of clinical development from bench to bedside. Journal of Biomedical Optics. 2007; 12(5): 1-13.

4.     Stephen T. Sum, , Sean P. Madden, Michael J. Hendricks, BS, Steven J. Chartier, and James E. Muller, Near-infrared spectroscopy for the detection of lipid core coronary plaques. [Spektroskopija V Blizhne-Infrakrasnoj Oblasti V Vyjavlenii Nestabil'nyh Ateroskleroticheskih Bljashek V Koronarnyh Arterijah)]. Diagnosticheskaja i intervencionnaja radiologija. 2012; 6(2): 39-51 [In Russ].

5.     Barlis P. A., Gonzalo N., SerruysP.et al.Multi-Center Evaluation of the Safety of Intra-Coronary Optical Coherence Tomography. Eurointervention. 2009; 5: 90-95.

6.     Prati F., Imola F., Mallus M. et al. Safety and feasibility of frequency domain optical coherence tomography to guide decision making in percutaneous coronary intervention. EuroIntervention.2010; 6:575-58.1

7.     Serruys P.W., Simon D. I., Costa M. et al. Clinical Research Compendium. A Summary of Cardiovascular Optical Coherence Tomography Literature. 2009; 3: 1-22.

8.     Prati F., Regar E., Gary Mintz S. et al. Expert review document on methodology, terminology, and clinical applications of optical coherence tomography: physical principles, methodology of image acquisition, and clinical application for assessment of coronary arteries and atherosclerosis. European Heart Journal. 2010; 31: 401-415.

9.     Kume T., Akasaka T., Kawamoto Т. е^ al. Measurement of the thickness of the fibrous cap by optical coherence tomography. Am Heart J2006; 152(4):755-4.

10.   Prati F., Cera M., Ramazzotti V. et al. Safety and feasibility- of a new non-occlusive technique for facilitated intracoronary optical coherence tomography (OCT) acquisition in various clinical and anatomical scenarios. Eurointerv. 2007;3:365-370.

11.   Gonzalo N., Patrick W., Serruys P.W., Peter Barlis., et al. Multi-modality intra-coronary plaque characterization: A pilot study. International Journal of Cardiology.2008; 138(1):32-9.

12.   Gonzalo N., Serruys P. W., Barlis P. et al. Multi-modality intra-coronary plaque characterization: A pilot study. 2008; Optical Coherence Tomography for the Assessment of Coronary Atherosclerosis and Vessel Response after Stent Implantation. 2010; 4.3:141-153.

13.   Chia S., Raffel O.C., Takano M. et al. Association of statin therapy with reduced coronary plaque rupture: An optical coherence tomography study. Coron Artery Dis. 2008; 19(4):237-42.

14.   Barlis P., Serruys P.W., Gonzalo N. et al. Assessment of culprit and remote coronary narrowings using optical coherence tomography with long-term outcomes. Am J Cardiol 2008; 15: 102(4):391-5.

15.   Jang I .K., Tearney G.J., MackNeill D. et al. In vivo characterization of coronary atherosclerotic plaque by use of optical coherence tomography. Circulation. 2005; 111(12):1551-1555.

16.   MacNeill B., Briain D.,. Bouma B.E. et al.Focal and multifocal plaque macrophage distributions in patients with acute and stable presentations of coronary artery disease. J. Am. Coll. Cardiol. 2004; 44:972-9.

17.   Takarada S., Imanishi T., Kubo T. et al. Effect of statin therapy on coronary fibrous-cap thickness in patients with acute coronary syndrome: Assessment by optical coherencetomography study. Atherosclerosis. 2009; 202(2):4917.

18.   Kubo T., Imanishi T., Takarada S. et al. Assessment of culprit lesion morphology in acute myocardial infarction: Ability of optical coherence tomography compared with intravascular ultrasound and coronary angioscopy. J. Am. Coll Cardiol.2001] 50(10):933-9.

19.   Larry J., Diaz-Sandov., Diaz-Sandoval. et al. Optical coherence tomography as a tool for percutaneous coronary interventions. Catheter Cardiovasc. Interv. 2005; 65(4):492-6.

20.   Gutierrez H., Arnold R., Gimeno F. et al. Optical coherence tomography: Initial experience in patients undergoing percutaneous coronary intervention. Rev. Esp. Cardiol. 2008; 61(9): 976-9.

21.   Tanigawa J., Barlis P., Kaplan S. et al. Stent strut apposition in complex lesions Using optical coherence tomography. Am. J. Cardiеl. 2006; 98(1) :97 M.

22.   Gonzalo N., Barlis P., Serruys P.W. et al. Incomplete Stent Apposition And Delayed Tissue Coverage Are More Frequent In Drug Eluting Stents Implanted During Primary Percutaneous Coronary Intervention For ST Elevation Myocardial Infarction Than In Drug Eluting Stents Implanted For Stable/Unstable Angina. Insights from Optical Coherence Tomography. Cardiovasc Interv. 2009; 2(5): 445-52.

23.   Gonzalo N., Serruys P.W. Optical coherence tomography (OCT) in secondary revascularisation: stent and graft assessment. Euro.Intervention. 2009; 5: D93-D100.

24.   Tanigawa J., Barlis P., Dimopoulos K., Di Mario. Optical coherence tomography to assess malapposition in overlapping drug-eluting stents. EuroInterv. 2008; 3: 580-583.

25.   Gonzalo N., Garcia-Garcia H.M., Serruys P.W. et al. Reproducibility of quantitative per strut stent analysis with OCT. EuroIntervention. 2009; 5(2): 224-32.

26.   Gonzalo N., Serruys P.W., Okamura T. et al. Optical Coherence Tomography Assessment Of The Acute E?ects Of Stent Implantation On The Vessel Wall. A Systematic Quantitative Approach. E.Heart. 2009; 95(23): 1913-1919.

27.   Gonzalo N., Serruys P.W., Okamura T. et al. Optical Coherence Tomography Patterns of Stent Restenosis. Am. Heart J. 2009; 158(2): 284-93.

28.   Gonzalo N., Serruys P.W., Okamura T. et al. Relation between plaque type and dissections at the edges after stent implantation: an optical coherence tomography study. Optical Coherence Tomography for the Assessment of Coronary Atherosclerosis and Vessel Response after Stent Implantation. 2010; 6.5:249-261.

29.   Xie Y., Takano M., Murakami D. et al. Comparison of neointimal coverage by optical coherence tomography of a sirolimus-eluting stent versus a bare-metal stent three months after implantation. Am. J. Cardiol. 2008;102:27-31.

30.   Chen B.X., Ma F.Y., Luo W. et al. Neointimal coverage of bare-metal and sirolimus-eluting stents evaluated with optical coherence tomography. Heart. 2008; 94:566-70.

31.   Matsumoto D., Neointimal coverage of sirolimus-eluting stents at 6-month follow-up: evaluated by optical coherence tomography. Eur. Heart J. 2007; 28:96 1-7.

32.   Yao Z.H., Matsubara T., Inada T, et al. Neointimal coverage of sirolimus-eluting stents 6 months and 12 months after implantation: evaluation by optical coherence tomography. Chin. Med. J. 2008;121:503-7.

33.   Takano M., Yamamoto M., Inami S. et al. Long-term follow-up evaluation after sirolimus-eluting stent implantation by optical coherence tomography: douncovered struts persist. J. Am. Cardiol. 2008; 51(9):968-9.

34.   Finn A.V., Joner M., Nakazawa G. et al. Pathological correlates of late drug-elutingstent thrombosis: strut coverage as a marker of endothelialization. Circulation. 2007;115(18):2435-41.

35.   Stone G., Moses J.W., Ellis S.G. et al. Safety and ef?cacy of sirolimus- and paclitaxel-eluting coronary stents. J. Med. 2007; 356(10):998-10.

36.   Kubo T., Kitabata H., Kuroi A .et al. Comparison of vascular response after sirolimus eluting stent implantation between patients with unstable and stable angina pectoris. A serial optical coherence tomography study. J. Am. Coll. Cardiol. 2008;1.

37.   Guagliumi G., Sirbi V., Costa M.A. A Long -term Strut Coverage of Paclitaxel eluting Stents Compared with Bare-Metal Stents implanted During Primary PCI in Acute Myocardial infarction A PROSPECTIVE, Randomised, Controled Study Perfomed with OCT. Horizons- OCT. Circulation. 2008;118:231.

38.   Barlis P., Regar E., Serruys PW. et al. An Optical Coherence Tomography Study of a Biodegradable versus Durable Polymer-Coated Limus-Eluting Stent: A LEADERS Trial Sub-Study. Eur. Heart J. 2010; 31:165-76.

39.   Serruys PW., Ormiston J.A., Onuma Y. et al. Bioabsorbable everolimus-eluting system (ABSORB): 2-year outcomes and results from multiple imaging methods. Lancet. 2009; 373(9667): 897-910. 

ANGIOLOGIA.ru (АНГИОЛОГИЯ.ру) - портал о диагностике и лечении заболеваний сосудистой системы