Abstract:

The authors report 44 successful implantations of original retrieval Nitinol stent-filters, unique "closed" design of which comprehensively described in the article. All the devices placed for pulmonary embolism (PE) management in patients with lower extremity and pelvic deep vein (DV) thrombosis. Authors announce absolute efficiency of their stent-filters for PE prophylaxis, and the procedure itself declared to be safe and minimally invasive.

Stent-filter implantation into iliac veins compared to standard filter placement in inferior vena cava (IVC) excludes risks of total infrarenal IVC thrombosis - the major complication of such procedures. It is also associated with early DV recanalization, that in sum radically reduces disability rate. Moreover, in case of IVC abnormalities, kinking or external compression stent-filter into iliac position remains the only option for endovascular PE management. All the above can be mentioned as advantages of using stent-filters.

At the same time authors observe that stent-filters quick incorporation into vessel wall prevented endovascular retrieval of the device in quite a number of cases. Persistent PE threat, requiring prolonged antithrombotic therapy under endovascular protection, might also contribute for low retrievability of the device. 

 

Reference

 

 

1.     Ballew K.A., Philbrick J.T., Becker D.M. Vena cava filters devices. Clin. Chest. Med. 1995; 16: 295-305.

 

 

2.     Becker D.M., Philbrick J.T., Selby J.B. Inferior vena cavafilters. Indications, safety, effectiveness. Arch. Intern. Med.1992; 152 (10): 1985-1994.

 

 

3.     Streiff M.B. Vena caval filters: a comprehensive review.Blood. 2000; 95: 3669-3677.

 

 

4.     Ferris E.J., McCowanT.C., Carver D.K., McFarland D.R.Percutaneous inferior vena caval filters: Follow-up ofseven designs in 320 patients. Radiology. 1993; 188:851-856.

 

 

5.     Mismetti P., Rivron-Guillot K., Quenet S., D cousus H.,Laporte S., Epinat M., Barral, F.G. A рrospective long-term study of 220 patients with a retrievable vena cava-filter for secondary hrevention of venous thromboembolism. Chest. 2007; 131:223-229.

 

 

6.     Rosenthal D., Wellons E.D., Lai K.M., Bikk A., Henderson V.J. Retrievable Inferior vena cava-filters: initial clinical results. Ann. Vasc. Surg. 2006; 20: 157-165.

 

 

7.     Asch M.R. Initial experience in humans with a new retrievable inferior vena cava filter. Radiology. 2002; 225:835-844.

 

 

8.     Binkert C.A., Sasadeusz K., Stavropoulos S.W. Retrievability of the recovery vena cava-filter after dwell times longer than 180 days. J. Vasc. Interv. Radiol. 2006;17: 299-302.

 

 

9.     De Gregorio M.A. et al. Retrieval of g nther tulip optional vena cava-filters 30 days after Implantation: Aprospective clinical study. J. Vasc. Interv. Radiol. 2006;17: 1781-1789.

 

 

10.   Oliva V.L., Szatmari F.et al. The jonas study: evaluationof the retrievability of the cordis optease inferio venacava-filter./ Vase. Interv. Radiol. 2005; 16: 1439-1445.

 

 

11.   Guglielmo ЕЕ, Kurtz A.B., Wechsler R.J. Prospectivecomparison of computed tomography and duplex sonography in the evaluation of recently inserted Kim-ray - Greenfield filters into the inferior vena cava. Clin.Imaging. 1990; 14:216-220.

 

 

12.   Kinney T.B., Rose S.C., Weingarten K.W. et al. IVC filter tilt and asymmetry: comparison of the the over-the-wire stainless-steel and titanium Greenfield IVC filters.J. Vasc. Interv. Radiol. 1997; 8: 1080-1082.

 

 

13.   Kinney T.B., Rose S.C. Regarding «limb asymmetry intitanium Greenfield filters».J. Vasc. Surg. 1998; 16:436-444.

 

 

14.   Прокубовский В.И., Капранов С.А., Савельев В.С.,Балан А.Н., Защеринская Н.А., Ломков С.С., Никитина А.В., Поликарпов О.В., Поликарпов И.В.Внутрисосудистый стент-фильтр. Патент РФ№ 2143246, приоритет от 03.06.99 г.

 

 

15.   Капранов С.А., Кузнецова В.Ф., Златовратский А.Г. Удаляемый стент-фильтр для профилактики тромбоэмболии легочной артерии. Международный журнал интервенционной кардиоангиологии. 2005; 7: 44.

 

 

16.   Кузнецова В.Ф., Капранов С.А., Златовратский А.Г. Применение стента-фильтра в эндоваскулярной профилактике тромбоэмболии легочной артерии. В сб. Новые технологии в хирургии. Ростов-на Дону.2005; 297.

 

 

17.   Прокубовский В.И., Капранов С.А. Эндоваскулярные вмешательства при тромбозе и эмболии. В кн.Флебология (руководство для врачей). Под ред. акад.В.С. Савельева. М.: Медицина, 2001; 351-390.

 

 

18.   Grams J., The S.H., Torres V.E.,. Andrews J.C. Nagor-ney D.M. Inferior vena cava-stenting: A safe and tffec-tive treatment for intractable ascites in patients with polycystic liver disease.J. Gastrointest. Surg. 2007; 11:985-990.

 

 

19.   Kishi K., SonomuraT., Fujimoto H., Kimura M., Yamada K., Sato M., Juri M. Physiologic tffect of stent therapy for Inferior vena cavajbstruction due to valignant liver tumor. Cardiovasc. Intervent. Radiol. 2006; 29: 75-83.

 

 

20.   Heijmen R., Bollen T., Duyndam D. et al. Endovascular venous stenting in May-Thurner syndrome.J. Cardiovasc. Surg. 2001; 42 (1): 83-87.

 

 

21.   Прокубовский В.И., Капранов С.А., МоскаленкоЕ.П. Анатомические и гемодинамические изменения нижней полой вены при профилактике тромбоэмболии легочной артерии. Ангиология и сосудистая хирургия. 2003; 2 (9): 51-60.

 

22.   Marcy P., Magne N., Frenay M. et al. Renal failure secondary to thrombotic complications of suprarenal inferior vena cava filter in cancer patients. Cardiovasc. Intervent. Radiol. 2001; 24: 257-259.

ANGIOLOGIA.ru (АНГИОЛОГИЯ.ру) - портал о диагностике и лечении заболеваний сосудистой системы